Logotipo del repositorio
  • Iniciar sesión
    ¿Nuevo Usuario? Pulse aquí para registrarse¿Has olvidado tu contraseña?
  • Iniciar sesión
    ¿Nuevo Usuario? Pulse aquí para registrarse¿Has olvidado tu contraseña?
Logotipo del repositorio
  • Inicio
  • Comunidades
  • Navegar
  • Estadísticas Externas
  • Reglamento
  • Manual de Usuario
  • Biblioteca
  • Revistas
Colecciones

Colecciones

Autor

Autores

Titulos

Títulos

Fechas

Fechas

Materias

Materias

  1. Inicio
  2. Examinar por materia

Examinando por Materia "Densities of building walls"

Mostrando 1 - 1 de 1
Resultados por página
Opciones de ordenación
  • Cargando...
    Miniatura
    Ítem
    Acceso Abierto
    Sustainable electromagnetic prototype for detecting internal deterioration in building walls
    (Multidisciplinary Digital Publishing Institute, 2024-07-20) Ascona García, Papa Pio; Aguirre Camacho, Marco Antonio; Silva Barboza, Elger Orlando; Ordoñez Carpio, Guido Elar; Cuadros-Rojas, Emerson
    The aim of this study was to develop a sustainable electromagnetic prototype to detect the interior deterioration of walls in buildings in order to mitigate uncertainty as it is a challenge to observe the interior state of walls without utilising destructive procedures. The method used was experimental, developmental and quantitative in its approach. The inductance, electric current, modulated frequency and power of the electromagnetic field were used to penetrate the constructed specimens, which were built of materials such as concrete, brick, adobe, plaster and fine sand and had walls with a thickness of less than 300 millimetres. The results show that the optimum value of the magnetic field was 0.18 μT, which was sufficient to penetrate 150 mm with densities between 1.0 and 2.4 g/cm3 and porosities between 11 and 60%. The current and wave each had a coefficient of determination R2 = 0.8914, and the average inductance value was 184 μH, which was established with an air core of radius 9.75 cm and with 19 turns with AWG-25 wire. The frequency-modulated signal ranged in the audible zone between 10 and 22 kHz. The presented prototype detects the interior deterioration of the walls of the building, and the signal is reflected on a metallic guide on the opposite side of the wall with a reading error of 5%. The use of this prototype does not represent a risk to the operator or the environment.
Slide 1
Slide 1
Slide 1
Slide 2
Slide 2
Slide 2
Slide 3
Slide 3
Slide 3

CONTÁCTANOS

Jirón Ancash N° 520 Bagua,
Amazonas, Perú
Central Telefónica: (041) 471005mesadepartes@unibagua.edu.peSistema de Mesa de Partes

ENLACES UNIFSLB

IntranetRevista Científica e InterculturalRepositorio DSpaceTransparencia Universitaria

PROCESOS UNIFSLB

admision@unibagua.edu.peConvocatoriasExamen de Admisión 2023-II

COMUNICADOS Y NOTICIAS

Agenda UNIFSLBNoticiasComunicadosTransparencia Universitaria
© Copyright Universidad Nacional Intercultural Fabiola Salazar Leguía de Bagua - UNIFSLB 2023. Diseño y Desarrollo por Bibliolatino.com - UNIFSLB UNIFSLB